MULTIPLE RXC SEGMENTS

Clovertech Forums Read Only Archives Cloverleaf Cloverleaf MULTIPLE RXC SEGMENTS

  • Creator
    Topic
  • #52922
    mike brown
    Participant

      Hi All

      I am using an Xlate to get orders from PYXIS inbound there are multpile

      RXC SEGMENTS

      RXC|P|PHM379^AMPICILLIN^^00781940795|000000500.0000|MG^MG

      ZRX|500 MG = 1 VIAL|00001|0|SANDOZ/NOVAPLUS

      RXC|B|PHM2923^SODIUM CHLORIDE 0.9% 50ML^^00409798436|000000050.0000|ML^ML

      ZRX|50 ML|00001|0|HOSPIRA

      ZOR||||||||6|||||||||22|^^C0788^^S~^^3ALLMGID^^551-P~^^3ALLORNO^^EDISM-MED-20538-1-1|||ROUTINE 1||1||||AMPICILLIN 500 MG IV ONCE


      OUTBOUND only one shows, how can i get both of them to go, i have tried almost everything, any help is appreciated…again

      RXC|P|PHM379^AMPICILLIN^^00781940795|000000500.0000|MG^MG

      50ML^^00409798436|000000050.0000|ML^ML

      ZR2|50 ML|00001|0|HOSPIRA

      ZOR||||||||6|||||||||22|^^C0788^^S~^^3ALLMGID^^551-P~^^3ALLORNO^^EDISM-MED-20538-1-1|||ROUTINE 1||1||||AMPICILLIN 500 MG IV ONCE

    Viewing 1 reply thread
    • Author
      Replies
      • #75944
        Levy Lazarre
        Participant

          Mike,

          This often indicates an issue with HL7 variants.

          Have you checked your inbound and outbound variants and made sure they allow repetitions for the RXC segments?

        • #75945
          mike brown
          Participant

            Thanks Jim, my HL7 variant was not setup correctly for what i was trying to do.

            everything works now.

        Viewing 1 reply thread