& in component

Clovertech Forums Read Only Archives Cloverleaf Cloverleaf & in component

  • Creator
    Topic
  • #50877
    Tria Zitterkopf
    Participant

      OBR 15.1 contains the specimen code and description, example ANKLE&ANKLE

      that is what is being sent to me.  I’m using Bulkcopy at the beginning so the whole text is already in my output field.  I need to change it to only say ANKLE.  If I move ANKLE into the field it still shows ANKLE&ANKLE.  If I move @null into that field then &ANKLE shows up.  How do I get rid of the text after the &?  It acts  like a list…I’ve tried those commands also.

      tria

    Viewing 1 reply thread
    • Author
      Replies
      • #67866
        Keith McLeod
        Participant

          Blank out the destination field and only copy OBR:15.1.0  Generally the & is the next level of addressing.  If you turn up the detail when you view the message in either the testing tool ot smat, you can verify which address is the correct one to use in your copy statement.

          ANKLE&ANKLE

          Might be OBR:15.0.0 for the first one and OBR:15.0.1 for the second one.

        • #67867
          Tria Zitterkopf
          Participant

            Thank you!  You were right.  I just had to add the extra detail.  I am so grateful!  Now on to the next part…tria

        Viewing 1 reply thread
        • The forum ‘Cloverleaf’ is closed to new topics and replies.