Splitting A17 into 2 A02’s

Clovertech Forums Read Only Archives Cloverleaf Cloverleaf Splitting A17 into 2 A02’s

  • Creator
    Topic
  • #50707
    Kevin Crist
    Participant

      This is my first try at this and i am close. but i am getting the same message for the first A02 as i am for the second A02. Am i missing something obvious (which is usually it).

    Viewing 3 reply threads
    • Author
      Replies
      • #67186
        Jim Kosloskey
        Participant

          Kevin,

          Shouldn’t your repetition counter or something be different than 0 (zero) for the second A02 Source (PID, etc)?

          email: jim.kosloskey@jim-kosloskey.com 29+ years Cloverleaf, 59 years IT - old fart.

        • #67187
          Kevin Crist
          Participant

            i apologize, but not sure what you mean.

          • #67188
            Vince Angulo
            Participant

              For the 1st patient:

              PATHCOPY 1(0).PID -> 1(0).PID

              For the 2nd patient:

              PATHCOPY 1(1).PID -> 1(0).PID

              If your input path is 1(0) for both, you’ll always get the 1st patient in each A02.

            • #67189
              Kevin Crist
              Participant

                Thanks. Exactly what i needed. I now see what jim was trying to explain to me. It all works now.