Please Wait …… MESSAGE 1 This message shows up in the EO as well as in the output for the Testing Tool when testing an XLT file. Thanks.Here is the output from the Testing Tool for an xlate
Command Issued: hcixlttest -d 1 -f eof MisysWin_A04_to_digiChart_A04_080610.xlt S:/quovadx/qdx5.5/integrator/pms/data/WAA013_Sample_A04.hl7
Command output:
[0:TEST] Mismatched IR Tags
[0:TEST] Mismatched IR Tags
0(0).MSH(0) : >|^~&|MISYS|MISYS|DIGICHART|DIGICHART|20080610071438-0500^S|NO SECURITY|ADT^A04|MISYS000006203|T|2.3.1|000000000006203||AL<
0(0).EVN(0) : >|A04|20080610071438-0500^S||000|00003<
0(0).PID(0) : >||157113|0019398|157113|LASTNAME^FIRSTNAME^M||19711225|N||U|1014 THIS ST^NE^THISTOWN^WA^99506-0000||(360)555-1111|360-0000||U||157113|000000000<
0(0).PV1(0) : >||P|^^^00003|R|||00037^LASTNAME^FIRSTNAME^M|||||||||||||00060<
0(0).GT1(0) : >|0001||LASTNAME^FIRSTNAME^M||1014 THIS ST^NE^THISTOWN^WA^99506-0000|(360)555-1111|360-0000<
1(0).0(0).IN1(0) : >|1<
2(0).ZDC(0) : >|39|415|UIDVALUE|PRACTICECODE|PRACTICECODESIGNON<
Can anyone give me an idea of what the “Mismatched IR Tags” error means? I thought it related back to an XLT incorrectly identifying a numeric field as text, but changing the field data type did not make the error message disappear.
Migration Consultant
Coffee Regional Medical Center
Eastern Time Zone