    Mark Perschbacher
    Participant

    I have an xlate that I am interating through multiple IN1 segments, copying IN1.00460 to .00428.  What I would like to do is evaluate .00428, and if it equals a certain value, copy .00460  to .00368, just for that segment, and not the others.  Can this be done in an xlate, or will it require a tcl snipet.  What do you think?

Viewing 7 reply threads
  • Author
    Replies
    • #62445
      John Hamilton
      Participant

      Are you checking for a value or numerious values.

      Depending on how many and what you should be able to use the If  command to do it.

    • #62446
      Robert Milfajt
      Participant

      The short answer is yes you can.

      The long answer requries more knowledge of your HL7 formats and the values you want to copy.

      Basically, as you are iterating through the IN1 segments, insert an if command within the iterate loop with a copy command if the if is true.

      Hope this helps,

      Robert Milfajt
      Northwestern Medicine
      Chicago, IL

    • #62447
      Mark Perschbacher
      Participant

      I am looking for a specific four digit ID.  I have an IF operation within the interate, but it is not selecting just the matching segment.  I’ll search through the forum and see if I can find some examples of “if true” operators.  Thanks

    • #62448
      Mark Perschbacher
      Participant

      Well, I have tried it with and without Bulkcopy, and can’t get it to work.

      Here is what I have

      Iterate: Group 3(0).0 %g1

      Copy: 3(0).0(%g1).IN1.00460 -> @tmp

      Table: @tmp -> 3(0).0(%g1).IN1.428

      IF: 3(0).0(%g1).IN1.00428 == =9900

      Copy: 3(0).0(%g1).00460 -> 3(0).0(%g1).00328

      Here is what the output looks like, any ideas?

      3(0).0(0).IN1(0)  :  >|1||4000|PREMERA BC/BLUE CARD|PO BOX 91080^MAIL STOP 212^SEATTLE^WA^98111-9180|(800)676-2583||092000178|||||||O||||||||||||||||||||ODD|YVP920483274< 3(0).0(1).IN1(0)  :  >|2||1000|MEDICARE PART B|PO BOX 91080^MAIL STOP 212^SEATTLE^WA^98111-9180|(800)933-0614|||||||||P||||||||||||||||||||MA|543465147D< 3(0).0(2).IN1(0)  :  >|3||9900|ODS|PO BOX 91080^MAIL STOP212^SEATTLE^WA^98111-9180|(800)933-0614|||||||||P||||||||||||||||||||ODS|543465147D<

    • #62449
      Elizabeth Wilson
      Participant

      What is the reason for the table? Can’t you check @tmp for the value?

      If your table output is different than the Input and if you do need to translate, then after you copy @tmp to 3(0).0(%g1).IN1.428 your IF should look in

      ~3(0).0(%g1).IN1.00428, not  3(0).0(%g1).IN1.00428

      Try that.

    • #62450
      Mark Perschbacher
      Participant

      I am running @tmp through the table to convert what the sending system is producing to what our LIS can recognize.  When I add the ~ to the condition of the IF statement, I get the “Value references must yield exactly one datum” error.

    • #62451
      John Hamilton
      Participant

      You should be able to use the variable in the if statement.

      Try this.

      Table: 3(0).0(%g1).IN1.00460 -> @tmp

      IF: @tmp == =9900

      Copy: 3(0).0(%g1).00460 -> 3(0).0(%g1).00328

    • #62452
      Mark Perschbacher
      Participant

      John, that did the trick.  It never ceases to amaze me how the simplest rearranging of operations, variables, and the order they are placed in can produce such different effects.  I moved the @tmp all around, created a second variable, but must not have had it just right.  Again, the generous users of this forum have come through, thanks ever so much!