I have this same error. It is on the inbound thread. It is a fileset-local. The input file was picked by a previous scripted step from another folder and moved to the Cloverleaf thread input folder. The script is also run by hci.
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:06] Received command: ‘from_idxrad pstart’
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:06] Doing ‘pstart’ command on ‘from_idxrad’
[prod:prod:INFO/0: from_idxrad:05/01/2016 21:53:06] Starting protocol thread from_idxrad as tid 2.
[prod:prod:INFO/0: from_idxrad:05/01/2016 21:53:06] Tracing status for protocol thread from_idxrad is 0.
[prod:prod:INFO/0: from_idxrad:05/01/2016 21:53:07] Applying EO config: ”
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] Receiving a command
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] Command client went away. Closing connection.
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] Receiving a command
[icl :tcpi:ERR /0: idxbill_cmd:05/01/2016 21:53:47] write failed: Broken pipe
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] Since there are some error had occured while attempted to send an Ack back to client
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] We try to process the command anyway but no further Ack will be send back to Client
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] Received command: ”idxbill_xlate’
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] Cmd null in ”idxbill_xlate’
[cmd :cmd :INFO/0: idxbill_cmd:05/01/2016 21:53:47] Inrecoverable socket error. Closing connection.
First of all, how can you have a broken pipe error on a local file?
Could it be the internal connection from the input thread to the output thread? They are both in the same process and they are the only threads in the process. The process was started just before this thread was started.
I will try setting the threads to auto-start.