LU 6.2 connection problem with Cloverleaf 5.3 and AIX 5.2

Clovertech Forums Read Only Archives Cloverleaf Cloverleaf LU 6.2 connection problem with Cloverleaf 5.3 and AIX 5.2

  • Creator
    Topic
  • #48562
    Tim Pancost
    Participant

      ‘Morning, all,

      We’re in the process of moving/upgrading one of our engines from 3.8.1P on AIX 5.1 to another box on 5.3 and AIX 5.2.  We’re having a problem getting our LU 6.2 connections (I know, I know, move to TCP/IP) going on the new machine, and I’m wondering if anyone else has seen these errors.  The SNA configuration was copied from the old box to the new box.  The link station and sessions with the mainframe are running and available.  I have a feeling it’s something small we’ve overlooked, but just can’t seem to figure it out.

      When the thread is started, I get the following error in the process log;

      06/02/2006 11:01:35 [appc:open:ERR /0:     from_tds] Unable to register TPN ‘HUT4’: Error 0

      In the SNA error log, we see this error;

      “A request to invoke a TP was rejected because the TP was not configured in the invocable TP data file.”

      I’ve verified that the SNA configuration between the two boxes is identical.  So, I’m at a loss.

      Any help/insight anyone can provide would be most appreciated.

      Have a great day!

      Tim Pancost

      Senior Technical Analyst

      Trinity Information Services

      pancostt@trinity-health.org

      Tim Pancost
      Trinity Health

    Viewing 1 reply thread
    • Author
      Replies
      • #58996
        Tom Patton
        Participant

          We are having an SNA problem as well with AIX 5.2 QDX 5.3 however ours sounds different.

          We are unable to  start our port.

          How about your port, DLC, sessions – are they all active?

          I know we have a separate NIC card attached to our DLC network – is that an issue for you?

        • #58997
          Mike Shoemaker
          Participant

            Hey Tim,  I recently went through a similar upgrade. We are connected to Seimens Invision and I ended up establishing my new box as a seperate PU with a whole new set of LUs.  I had a similar error that you saw in your error log that was resolved once Seimens rebuilt or enabled something on the CICS side.  Are you connecting the new box to the old LUs or are these new LUs?  Took me awhile to convince seimens to even look at thier side as they kept assuring me everything was setup right.

            Mike

            Tim Pancost wrote:

            ‘Morning, all,

            We’re in the process of moving/upgrading one of our engines from 3.8.1P on AIX 5.1 to another box on 5.3 and AIX 5.2.

        Viewing 1 reply thread
        • The forum ‘Cloverleaf’ is closed to new topics and replies.